11 products found
Air Monitor Corporation Products
-
HVAC Products
-
Model OAM II - Outdoor Airflow Measurement System & Airflow Station
OAM II Outdoor Airflow Measurement Systems consist of the OAM II Transmitter with built-in barometric pressure sensor, one or more uni-sensors or OAM II Airflow Stations, and one or two temperature sensors. The system has been designed to measure the actual airflow rate to within ±5% by measuring differential pressure across a fixed inlet, such as a louver, screen or layer of expanded ...
-
ELECTRA-flo - Model 5 Series - Thermal Airflow Measurement System
The ELECTRA-flo Thermal Probe Array utilizes thermal dispersion technology in multi-point probes to measure average airflow and temperature. The rugged anodized aluminum probes have aerodynamic sensor apertures that condition turbulent airflow, resulting in a NIST traceable accuracy of ±2% of actual ...
-
ELECTRA-flo/FI - Thermal Dispersion Fan Inlet Probe Array
The ELECTRA-flo/FI Thermal Fan Inlet Airflow Probe utilizes dual point thermal dispersion technology sensors installed in the fan’s inlet bell mouth at the throat. Aerodynamic sensor apertures, assisted by the air processing effect of the nozzle-shaped fan inlet, provide accurate measurement for most fan types. Readings are taken at the measurement point, not calculated at the transmitter. This allows for daisy-chaining multiple units together which ...
-
ELECTRA-flo - Model S5-CM - Thermal Airflow Measurement Station
The ELECTRA-flo/CM Thermal Airflow Measuring Station combines thermal dispersion measurement technology with an integral honeycomb cell air straightener to assure measurement accuracy within ±2-3%. The addition of the honeycomb cell air straightener is vital to obtain these degrees of accuracy under turbulent, rotating and multi-directional airflows normally present near fan inlets or discharge ...
-
Model FAN-E - Pitot Airflow Measurement Traverse Station
The FAN-E Station is a multi-point, self-averaging Pitot traverse station with an integral air straightening honeycomb cell. It’s capable of continuously measuring fan discharges or ducted airflow with a certified accuracy of ±2% when tested according to AMCA Standard 610. The high degree of accuracy is a result of the sensor locations and sensing ports, the honeycomb airflow processing and the instantaneous pneumatic averaging of multiple ...
-
Model ELECTRA-flo/SD - Thermal Airflow & Temperature Measurement System
The Electra-flo/SD is an accurate, cost-effective thermal airflow measurement system specifically designed for VAV box installations and small duct applications using 4″-16″ ducts. The low flow measurement capability of the ELECTRA-flo/SD allows for reduced minimum airflow settings and increased system efficiencies while still meeting IAQ requirements. Installation and set-up are easy in both new and existing ...
-
Industrial Products
-
ACCU-flo - Model NP - High Accuracy Stainless Steel Station
The ACCU-flo/NP is a combination precision nozzle and multi-point, self-averaging Pitot airflow measurement station. When combined with an ultra high accuracy transmitter, such as Air Monitor’s VELTRON II, MASS-tron II or VELTRON DPT-plus, the ACCU-flo/NP provides high accuracy (±0.5%) flow measurement for process monitoring and control applications. The combined effect of the integral flow straightener cell and the nozzle means little or no ...
-
Model AUTO-purge III - Combustion Air Station
Air Monitor’s AUTO-purge III is designed for applications where the continuous exposure to airborne particulate might impair the measurement accuracy of our Combustion Air Station (CA Station) or our VOLU-probe/SS array. When activated by one of our “smart” flow transmitters or a distributed control system, a combination of valves are operated to introduce high pressure, high volume air into the flow measurement device’s sensing ...
-
Power
-
Model CA - Combustion Airflow Measurement Station
The CA Station measures the total and static pressure components of airflow. The combination and dispersion of total and static pressure sensing ports minimizes the effect of directional airflow, and the addition of the honeycomb airflow processing cell makes the CA Station extremely effective at accurately measuring airflow in limited straight duct runs. Air Monitor Power’s ruggedly constructed Combustion Air (CA) Station, with both integral ...
-
Air Monitor Power CAMS - Combustion Airflow Management System
The Air Monitor Power CAMS™ – Combustion Airflow Management System – is designed to fulfill the need for a reliable and accurate means of flow measurement in combustion airflow applications. Combined into a single engineered package are the CAMM™ – Combustion Airflow Management Module – containing the microprocessor based instrumentation to measure the airflow and manage the purge cycle, and AUTO-purge to protect ...
-
Veltron - Model II CAMM - Transmitter
The VELTRON II Transmitter is an ultra-low differential pressure and flow “smart” transmitter. With its ±0.1% of natural span accuracy, it is intended for the most critical and demanding HVAC and industrial applications requiring the utmost accuracy and long-term stability. The VELTRON II transmitter is furnished with an automatic zeroing circuit capable of electronically adjusting the transmitter zero at predetermined time intervals ...