17 products found
Microbiotests Inc. Products
-
Toxkits Equipment
-
Microbiotests - Model DAPHTOXKIT F - Acute Daphnia Magna Toxicity Tests
The acute Daphnia magna toxicity test is intended for toxicity screening of chemicals, effluents, surface waters, wastewaters, groundwaters, sediment pore waters and elutriates. In Daphtoxkit F, you find all necessary materials to perform six acute 24-48h mobility inhibition tests with the freshwater crustacean Daphnia magna. The Daphnia immobilisation test is cost-effective, culture-independent, user-friendly and highly standardised, conform to
-
Microbiotests - Model ALGALTOXKIT F - Freshwater Algae Toxicity Test
The freshwater algae toxicity test is intended for toxicity screening of chemicals, effluents, surface waters, wastewaters, groundwaters, sediment pore waters and elutriates. Algaltoxkit F contains all the materials you need to perform two 72h growth inhibition tests with the freshwater microalgae Pseudokirchneriella subcapitata (former names: Selenastrum capricornutum and Raphidocelis subcapitata). This cost-effective and culture-independent Algal ...
-
Microbiotests - Model ALGALTOXKIT M - Marine Water Algae Toxicity Test
The marine water algae toxicity test is intended for toxicity screening of chemicals, contaminated coastal and estuarine waters, effluents or elutriates with high conductivity values and marine sediment pore waters. Algaltoxkit M contains all materials necessary to perform two 72h growth inhibition tests with the marine diatom Phaeodactylum tricornutum. This cost-effective and culture-independent marine Algal toxicity test strictly adheres ...
-
Microbiotests - Model ARTOXKIT M - Cyst-Based Artemia Franciscana Toxicity Test Kits
The cyst-based Artemia franciscana toxicity test is applicable for toxicity screening of chemicals, contaminated coastal and estuarine waters, effluents or elutriates with high conductivity values, biotoxins and marine sediment pore waters. Artoxkit M contains all necessary materials to perform six acute 24h mortality tests with the marine crustacean Artemia franciscana (formerly named Artemia salina). This bioassay is cost-effective, culture-independent ...
-
Microbiotests - Model ROTOXKIT M - Cyst-Based Marine Rotifer Toxicity Test Kit
The cyst-based marine rotifer toxicity test is intended for toxicity screening of chemicals, contaminated coastal and estuarine waters, effluents or elutriates with high conductivity values, biotoxins and marine sediment pore waters. In Rotoxkit M, you find all the materials you need to perform six acute 24-48h mortality tests with the marine rotifer Brachionus plicatilis. This bioassay conforms to ISO Standard 19820 and is ...
-
Microbiotests - Model DUCKWEED TOXKIT F - Spirodela Duckweed Toxicity Test Kit
The Spirodela duckweed toxicity test is intended for toxicity screening of chemicals, effluents, pesticides, surface waters, wastewaters, groundwaters, sediment pore waters and elutriates. Duckweed toxkit F contains all the materials you need to perform two 72h growth inhibition tests with the higher aquatic plant duckweed species Spirodela polyrhiza. This cost-effective and culture-independent bioassay strictly adheres to ISO Standard ...
-
Microbiotests - Model THAMNOTOXKIT F - Cyst-Based Thamnocephalus Platyurus Toxicity Test Kit
The cyst-based Thamnocephalus platyurus toxicity test is intended for toxicity screening of chemicals, effluents, biotoxins, surface waters, wastewaters, groundwaters, sediment pore waters and elutriates. In Thamnotoxkit F, you find all necessary materials to perform six acute 24h mortality tests with the freshwater crustacean Thamnocephalus platyurus. This cost-effective, culture-independent and highly-standardised bioassay conforms to ISO ...
-
Microbiotests - Model OSTRACODTOXKIT F - Chronic Direct Contact Sediment Toxicity Test Kit
The chronic direct contact sediment toxicity test is applicable for toxicity screening of contaminated river sediments, soils and solid wastes. Ostracodtoxkit F contains all materials to perform three to five 6-day mortality and growth inhibition tests with the benthic freshwater ostracod Heterocypris incongruens. This sediment-contact bioassay is cost-effective, culture-independent and highly standardised, conform to ISO Standard ...
-
Microbiotests - Model Phytotoxkit - Liquid Samples
The phytotoxicity test is intended for phytotoxicity screening of chemicals, leachates of soils or solid wastes, sediment pore waters and elutriates, wastewaters, pesticides and biocides and other research applications. The Phytotoxkit liquid samples contains all necessary materials to perform one complete 3-day seed germination and early growth test with the monocotyl Sorghum saccharatum (Sorgho) and the dicotyls Lepidium sativum (garden cress) and ...
-
Microbiotests - Model Ceriodaphtoxkit F - Acute Ceriodaphnia Dubia Toxicity Test Kit
The acute Ceriodaphnia dubia toxicity test is intended for toxicity screening of chemicals, effluents, surface waters, wastewaters, groundwaters, sediment pore waters and elutriates. In our Ceriodaphtoxkit F, you find all the necessary materials to perform six acute 24h mortality tests with the freshwater crustacean Ceriodaphnia dubia. The Daphnia mortality test is cost-effective, culture-independent, user-friendly and highly standardised, it adheres to ...
-
Microbiotests - Model PROTOXKIT F - Ciliated Protozoan Toxicity Test
The ciliated Protozoan toxicity test is intended for toxicity screening of chemicals, effluents, surface waters, wastewaters, groundwaters, sediment pore waters and elutriates. Protoxkit F contains all necessary materials to perform six chronic 24h growth inhibition tests with the freshwater ciliated protozoan Tetrahymena thermophila. This small-scale bioassay is cost-effective, culture-independent and highly ...
-
Microbiotests - Model ROTOXKIT F - Cyst-Based Rotifer Toxicity Test
The acute, cyst-based rotifer toxicity test is intended for toxicity screening of chemicals, effluents and wastewaters, sediment pore waters and elutriates, surface and groundwaters. In Rotoxkit F, you find all the materials you need to perform six acute 24h mortality tests with the freshwater rotifer Brachionus calyciflorus. This small-scale, cost-effective, culture-independent, user-friendly and highly standardised bioassay conforms to ...
-
Microbiotests - Model Rotoxkit F Chronic - Chronic Cyst-Based Rotifer Toxicity Test Kit
The chronic, cyst-based rotifer toxicity test is intended for toxicity screening of chemicals, effluents and wastewaters, sediment pore waters and elutriates, surface and groundwaters. In Rotoxkit F chronic, you find all the materials you need to perform three chronic 48h reproduction tests with the freshwater rotifer Brachionus calyciflorus. This small-scale, cost-effective, culture-independent, user-friendly and highly standardised bioassay complies to ...
-
Microbiotests - Model RAPIDTOXKIT F Thamno - Cyst-Based Thamnocephalus Platyurus Toxicity Test Kit
The cyst-based Thamnocephalus platyurus toxicity test is intended for rapid toxicity screening of chemicals, effluents, surface and groundwaters, wastewaters. In Rapidtoxkit F Thamno, you find all necessary materials to perform 3 independent series of 1h sub-lethal effect ingestion tests with the freshwater crustacean Thamnocephalus platyurus on seven up to fifteen water samples. This cost-effective, culture independent, standardised bioassay conforms to ...
-
Microbiotests - Model Phytotoxkit - Solid Samples
The phytotoxicity test is intended for phytotoxicity screening of soils, sludges, sediments, composts, effluents for irrigation, chemicals,pesticides and biocides. The Phytotoxkit solid samples contains all necessary materials to perform one complete 3-day seed germination and early growth tests with the monocotyl Sorghum saccharatum (Sorgho) and the dicotyls Lepidium sativum (gardencress) and Sinapis alba (mustard), in three replicates. This ...
-
BioLight Toxy - Bioluminescent analyzer
BIOLIGHT LUMINESCENT BACTERIA TEST with Aliivibrio fischeri The BioLight Toxy luminometer offers the most up to date dual option instrument for bioluminescent toxicty testing with Aliivibrio fischeri (formerly named Vibrio fischeri) in the market. The BioLight Toxy – Bench Top instrument includes a cooled read well and cooled reagent well along with a separate cooling block to ensure all samples are kept at the appropriate temperatures during ...
-
BioLight - Reagents And Consumables For Bioluminescent Toxicity Testing with Aliivibrio fischeri
BioLight Reagents and Consumables are applicable for the luminescent bacteria toxicity test using the freeze dried bacteria Aliivibrio fischeri (strain NRRL B-11177) which has bioluminescent properties. The inhibition of light emitted by the luminescent bacteria is the test criterion for measuring acute toxicity. The bioLuminescent bacteria test has been used for more than 30 years for environmental toxicity monitoring in water, soil and waste industry ...