22 products found
Modern Safety Techniques (MST) Inc. Products
-
RP Series
MST’s RP Series offer a Low Temperature Catalyst thats converts CO to carbon dioxide helping to provide safe air without the use of expensive desiccant dryers. Making our systems one of the most cost effective and efficient systems on the market today.
-
MST - Model RP050BMST - Portable CO Removal System
The RP050BMST is the only truly portable CO removal system around. The rugged heavy duty case provides protection from the elements and the extra freedom to move from job to ...
-
MST - Model RP050 - Panel Mounted Systems
The RP050 panel mounted systems are available with the MST 5700 CO monitor or the MST 2002 CO monitor. These single outlet systems can be mounted and piped to the workers ...
-
MST - CO Removal Systems
MST also offers additional panel mounted systems from 100 to 1000 scfm. All CO removal systems come standard with the 5700 CO monitor or the 2002 CO ...
-
BA Series
MST also manufactures Breathing Air Filtration Systems without CO removal. Our systems have an extra added “Fourth Stage” of activated carbon to reduce tastes and odors, and offer superior hydrocarbon removal. Replacement filters are economically priced to help lower maintenance costs. MST’s Breathing Air Panel Series “Filtration” System with Superior Filtration capabilities of ANY of our competitors.
-
MST - Model BA100BA-S1 and BA020AMST-S1 - Panel Mounted Breathing Air Systems
If you don’t want portability, take a look at the Panel Mounted Breathing Air Series. Available from 20 SCFM to 600 ...
-
Monitoring Systems
MST’s Airline Monitor Packages provide continuous monitoring of Carbon Monoxide or Carbon Monoxide/Oxygen to help meet OSHA compliance when purification or filtration is not desired. Our monitor packages are packaged in a rugged, weather resistant carrying case that can be carried to the area requiring monitoring, or be permanently installed. Airline Monitoring Packages are available in several configurations and price ranges. We also will custom manufacture other configurations to meet individual special requirements.
-
MST - Model 5700 - Airline Monitoring Systems
Check carbon monoxide levels throughout your compressed air system with MST’s compact portable ‘CO’ Monitor ...
-
MST - Model 5700-S - Airline Monitoring Systems
CO Monitoring with a Low Pressure Warning ...
-
MST - Model 8033902 - Airline Monitoring Systems
8033902 Retrofit Package (5700 monitor). Adds CO Monitoring to an existing Breathing Air ...
-
MST - Model 8007701 - Airline Monitoring Systems
8007701 Retrofit Package (2002 monitor). Adds CO Monitoring to an existing Breathing Air ...
-
MST - Model 8007702 - Ambient Air Monitoring System
The 2002 Monitor is designed to monitor ambient air in factories, parking garages, boiler rooms, or other areas where single point gas detection is ...
-
Point of Attachment systems
-
Point of Attachment Panel
Removes contaminants introduced between the purification / filtration panel and the point of attachment ...
-
Low Pressure Alarm
MST’s Point-of-Attachment system is an air distribution system that will alarm when the supplied air falls below a preset air pressure setting. The pressure setting is designated in the model number. When the inlet air pressure to the POA falls below the preset level specified in the model number, a pressure switch connects the internal 9 volt transistor battery to the alarm (rated 119 dB(A). The alarm will continue to operate until the pressure in the ...
-
Automatic Shut-off/Back-up Diverter Device
MST®`s `Automatic Shut-Off Device` (ASOD) and `Automatic Shut-off Diverter Device` (ASODD) provide additional safety controls to your Breathing Air System.The Automatic Shut-Off Device (ASOD) is designed to shut down your air supply should Carbon Monoxide (triggered by CO Monitor) or Low Pressure (triggered by Low Pressure Alarm) conditions exists in your Breathing Air Supply. This device Should Not be used in an Immediately Dangerous To Life and Health (IDLH) Atmosphere unless it is used in conjunction with a Back-up Air Supply to allow Egress of the contaminated atmosphere.
-
Automatic Shut-Off/Diverter Device (ASODD)
The Automatic Shut-Off/Diverter Device (ASODD) provides an extra inlet port to provide for an uninterrupted air supply should Carbon Monoxide (triggered by CO Monitor: or Low Pressure (triggered by Low Pressure Alarm) condition exist in your Breathing Air Supply. The second inlet port requires connection to a second Regulated Air Source meeting Grade D Specifications (either a Back-Up Compressor with the proper safety devices, or a Bottled Air ...
-
Accessories
-
Ambient Air Compressor
MST, Inc. now has available a portable ambient air compressor for painters who do not have enough volume in their current compressed air system to accommodate the additional load required to operate a respirator. MST’s Fresh-Air pump is small, quiet, lightweight and ready to supply clean breathing air to one (1) worker.* The pump comes with an on-off switch and is wired for 110-120 VAC power, however the pump can also be wired to operate from 220 VAC. The ...
-
MST Aftercooler System
The MST Model 8059601 Aftercooler System is designed to be used with the MST Model 8050501 Ambient Air Pump to provide cooler air to the continuous flow supplied air respirator. The Aftercooler will reduce the air temperature produced by the Ambient Air Pump by up to 43 percent. The Aftercooler is connected to the outlet of the Ambient Air Pump via a ½' I.D. x 5 ft. long hose. The customer’s continuous flow supplied air respirator hose assembly is ...
-
Air Horn Alarm System
The MST Model 8039601 Air Horn Alarm System is an alarm system utilizing a small compact valving system that is designed to activate an air horn should the carbon monoxide monitoring system in the Filtration and/or Purification system go into an alarm condition. (For use in explosive ...
-
MST Remote Alarm
Sound Pressure vs. Voltage (dB vs .0002 bar @ 1 ft.): +114dB @ +5 VDC, +122dB @ +9 VDC, +125dB @ +12 VDC. Operating Sound Pressure and Voltage vs. Standard Alarm Conditions of MST Monitor: +119dB @ +7.5 VDC. Current Drain vs. Voltage: 40mA @ +5 VDC, 130mA @ +9 VDC, 195mA @ +12 VDC. Operating Temperature Range: 32 TO 158o F (O TO 70o C). Humidity: 0 TO 90% RH (Non-Condensing). Power Cord: 20 FT., 18 AWG/2C, SPT-1, VW-1, 221o F (105o C). Optional: Up to 250 ...
-
Calibration Kit
MST’s 8003101 Calibration Kit is furnished with a non-adjustable regulator to ease the calibrating procedure. WARNING: To avoid damage to the monitor’s sensor, regulator provided in this kit must be used. Before attempting to use this kit, be certain that the components are connected as shown in the sketch below and read the section on “CALIBRATION AND ADJUSTMENT” in the instruction manual furnished with the instrument. It will save time and conserve ...
-
Electronic Low Pressure Warning System
The MST Model 8023301 Electronic Low Pressure Warning System is designed to alert users of MST's Breathing Air Purification Systems that the incoming air pressure has decreased below a specified minimum value (to be determined according to customer's requirements). The system consists of a miniature pressure switch connected to a battery operated external remote alarm. The pressure switch is factory preset to the pressure designated in the model number ...
-
MST Humidifier
This is a constant density type humidifier which delivers a constant ratio of water to air flow. Therefore, if air flow increases or decreases, water delivery will be adjusted proportionately. Only if a different ratio is desired should your needle valve setting be changed after your initial ...
-
MST`s Optional Prefilters
All MST 'Respiratory Protector' and 'Breathing Air Panel' series use element grade designation '6QU' for the first stage particulate removal & second stage liquid aerosol ...
-
MST Remote Strobe
Operating Voltage: 12 VDC. Power Consumption: 140 mA. Flash Rate: 60 per min. Candle Power: 150,000 CP. Operating Life: 800 hrs. Strobe Base Material: UL-94 Flame Retardant Plastic. Strobe Lens Material: Clear Polycarbonate. Power Cord: 20 FT., 18 AWG/2C, SPT-1, VW-1, 221o F (105o C). Optional: Up to 250 ft. of Cord can be ...
-
MST Electronic Filter Life Timer
The MST model 8022801 Electronic Filter Life Timer is designed to monitor your replacement filter element frequency in your MST Breathing Air Purification System. When pressure to MST Breathing Air Filter/Purification System reaches 12 PSIG or greater the timer will start; the timer will stop timing below this pressure. The MST Electronic Filter Life Timer consists of a miniature pressure switch connected to a continuous reading digital timer. The timer ...