NIVUS - Model OFR - Radar Sensor for Contactless Flow Measurement
From Flow Measurement - Clean and Slightly Polluted Media - Flow Sensors
Suitable for applications featuring high velocities and low levels. OFR Radar - contactless flow measurement: Suitable for applications featuring high velocities and low levels. By developing the OFR radar sensor in combination with our previous product range we are capable of providing the best possible measurement solution to detect any kinds of flow in each application. Whether for measurement places with highest accuracy requirements or for applications with difficult media – we provide easy-to-install measurement systems achieving optimum results. The unique combination of radar measurement and ultrasonic measurement provides previously unprecedented accuracy covering the entire measurement range.
Product Details
- Contactless flow velocity measurement
- Installation without interrupting processes
- Determination of surface velocity
- Low maintenance through contactless radar sensor
- Easy installation and operation
- For use in aggressive / abrasive media
- For measurement places with high pollution loads and sedimentation
- For shooting discharge and low flow level
- Improved accuracy in combination with bottom-mounted ultrasonic velocity sensors
Technical Specifications
General
- Measurement principle: Radar doppler flow velocity detection
- Measurement range: 0,15 m/s - 20 m/s
- Temperature range: -30 °C to 70 °C
- Frequency response: 24 GHz - ISM band
- Beam angle: ca. 24° horizontal, ca. 45° vertical
- Distance: 0,3 m - 20 m
- Protection: IP 68
- Enclosure material: High-performance composites
- Measurement principle: Radar doppler flow velocity detection
- Measurement range: 0,15 m/s - 20 m/s
- Temperature range: -30 °C to 70 °C
- Frequency response: 24 GHz - ISM band
- Beam angle: ca. 24° horizontal, ca. 45° vertical
- Distance: 0,3 m - 20 m
- Protection: IP 68
- Enclosure material: High-performance composites
Technical Data
Common
- Measurement principle: Radar doppler flow velocity detection
- Measurement range: 0,15 m/s - 10 m/s
- Temperature range:
- -30 °C to 70 °C
- Ex-Type: -20 °C to 60 °C
- Frequency response: 24 GHz - ISM band
- Distance: 0,3 m - 10 m
- Protection: IP 68
- Enclosure material:: High-performance composites
- Ex-Approval: II 2 G Ex ib IIB T4 Gb; TÜV 16 ATEX 185271X; IECEx 16.0034X