QuickCheck - Model IV/GR - Cryoscope Analyzer
From Cryoscopes
Laboratory instrument for accurate precise testing of added water in milk Testing milk for extraneous water in accordance with internationally reviewed and recommended methods (AOAC, IDF 108:2002 & ISO 5764:2002), the QC-IV ensures that incoming milk is not adulterated with added water for payment purposes. Also, the QC-IV provides a critical control check for processed milk and confirms proper balance in cheese, yogurt and ice-cream recipes.
-
Most popular related searches
Products Details
Accurate, Precise Screening for Added Water in Milk
Testing for adulteration of milk in accordance with recently updated international reference methods
(see ISO 5764:2002, IDF 108:2002 and AOAC), the QC-IV provides ultra-accurate results in ~ 90 seconds.
Flexible, Reliable and Affordable!
Confirming consistent quality by testing for extraneous water resulting from accidental or purposeful contamination is important for building and maintaining brand-name recognition. Rely upon the test
the industry has trusted for years: Freezing-Point! The robust, modular construction of the Model
QC-IV is designed to provide you with years of dependable service. The LACTICAL™ milk-based controls and easy, intuitive procedures facilitate calibration validation as required. User-friendly operation ensures that real-time results are ready anytime; on demand! Whether your testing needs are for payment purposes, product development or simply to confirm positives from screening tests, the QuickCheck Cryoscope offers steadfast accuracy and unwavering precision to faithfully fulfill a wide variety of requirements.
The following supplies are included in the standard Start-Up kit:
- 1 x Bath Liquid Solution (500 ml)
- 1 x DC Power Cord
- 1 x User’s Manual
- 1 x 12 Sample Tubes
- 1 each 422 & 621 Calibration Standards (125 ml)
- 1 x 530 Calibration Control (125 ml)
Testing Parameters:
- Freezing-Point Range 0 to -1000 mºC or mºH
- Sample Capacity Single Sample
- Sample Size 2.5 ml
- Test Time < 2 minutes
- Repeatability ± 0.002 ºC
- Resolution ± 0.0001 ºC
- Linearity < ±0.5%
- Readout Units ºC or ºH
- Start-Up time ~10 minutes
- Calibration 2 points (User Selectable)
Electrical Parameters:
- Line Voltage 110/220V ( ± 10%)
- Line Frequency 50/60 HZ
- Power Consumption
- Main Fuse 110V - 3A, 220V - 2A
Environmental:
- Ambient Air Temperature .. 15°-38°C (59°- 100° F)
- Sample Temperature 4°-35°C (39°-95°F)
- Relative Humidity 30-80%