OTT HydroMet - Model SLD - Side-Looking Flow Doppler Sensor
From Water Flow
Water flow meter for longterm data collection of velocity and discharge measurements. The OTT SLD is a measurement system for continuous measurement of water velocity and level in streams, rivers, and canals. The sensor employs the acoustic Doppler principle to reliably measure flow velocity in a variety of naturally occurring conditions, including during most flood events.
-
Most popular related searches
Product Details
- Usage Type: Fixed installation
- Measurement technology: Acoustic
- Parameters measured: Flow velocity
- Product Highlights: Side-Looking-Doppler for continuous discharge measurement in rivers and open channels. Discharge calculation based on velocity - index - method. Integrated vessel filter algorithm, Modbus interface and output of total volume of flow (max. interval 1 day).
- Measurement range: ± 10 m/s
- Accuracy: ± 1 % of measured value ± 0.5 cm/s
Advantages
- Equipped with two horizontal ultrasonic transducers 'looking sideways' into the flow (Side Looking Doppler) to measure water velocity.
- An optional vertical transducer and integrated pressure cell measures the water level.
- All measurement values are analyzed, verified and processed by an integrated signal processor, before being used in the calculation of discharge.
- Velocity measurements from up to nine cells are used, along with measured water level, to calculate discharge either internally in the OTT SLD or externally in a data logger.
- All measurements can be retrieved using SDI-12, RS485 , RS232 or Modbus RTU protocols and are available for storing in a data collection platform, such as the OTT netDL station manager.
Example of Use
- Reliable performance in waters with high sediment load and flood situations
- Applicable in natural rivers, streams, shipping-, irrigation- and service water canals
- Also suitable for small waterbodies (smallest cell size 20 cm)
Technical Specification
Flow velocity measurement
- Measuring range: ±10 m/s
- Accuracy: 1% of measured value ± 5 mm/s
- Number of measuring cells: 9
Cell size / Blanking
- 600 kHz: 2 … 10 m / 0.5 … 30 m
- 1.0 MHz: 1 … 4 m / 0.3 … 15 m
- 2.0 MHz: 0.2 … 2 m / 0.1 … 8 m
Beam angle / Max. profiling range*
- 600 kHz: 2.4° / 80 m
- 1.0 MHz: 2.4° / 25 m
- 2.0 MHz: 2.1° / 10 m
- Minimum coverage: 0.15 m (water level option)
Electrical data
- Supply voltage: 12 ... 16 V DC, typ. 12 V
- Power consumption: 50 ... 500 mW, depending on measurement cycle
Water level measurement
- (optional):
- Measuring range: 0.15 ... 10 m
- Accuracy: ±3 mm, depending on stratification
- Pressure cell (optional):
- Measuring principle: Piezo-resistive
- Measuring range: 0 ... 10 m
- Accuracy: ±0.25 % FS
- Interfaces: RS-232, SDI-12 or SDI-12 via RS-485, Modbus (optional)
Environmental conditions
- Operating temperature: -5 ... + 35 °C
- Storage temperature: -20 ... +70 °C
- Length x Ø: 45 ... 52.2 cm x 7.5 cm
- Housing material: POM
Wall bracket (accessory)
- Components: Bracket, protective cover, and C rail mount
- Material: Stainless steel
- Details: On request
- Discharge calculation: Within the unit or externally on a datalogger, e.g. OTT netDL
- OTT SLD EasyUse Installation and service software: System setup, commissioning, reviewing and optimizing
- OTT Prodis 2 (accessory) Calibration software: Determining correction factors, (velocity-index method and others), optimizing discharge calculation, managing stations
*The beam angle is understood to be the measured angle with regard to the main axis. The maximum profiling range depends on the water profile, salinity, suspended matter content etc.
Customer reviews