Humidity Switch - Series HS Manual

Specifications - Installation and Operating Instructions(3.000)(1.338)(2.375)(1.100)DESCRIPTIONThe microprocessor based Series HS HumiditySwitch provides control for humidifying ordehumidifying. Relative humidity, output status,and error messaging can be viewed on the brightgreen LED. The switch features 9 user definedparameters including setpoint, hysteresis, controltype, cycle time, and probe adjustment. Accessto programming parameters can be locked forsecurity purposes using the password protectionfeature. Use the configuration key (soldseparately) to quickly program multiple units. TheSeries HS includes a fitting clip for panelmounting, gasket, rear terminal cover, andinstruction manual.INSTALLATIONNOTE: Unit must be mounted away from vibration, impacts, water and corrosive gases.• Cut hole in panel 2.80 x 1.14 inches (71 x 29mm). • Apply silicone (or rubber gasket) around the perimeterof the hole to prevent leakage.• Insert unit into hole of panel.• Slide removable fitting clips onto unit from the back untilsecure to panel.• Remove back cover to wire unit.• Wiring diagram is displayed on the top of the unit.• (Note: PROBE CABLE LENGTH MUST NOT EXCEED 328 ft (100 m). DO NOT INSTALL PROBE CABLE NEARPOWER CABLES)• Replace cover once wiring is completed.Bulletin # H-HSSeries HS Humidity SwitchLOVE CONTROLS DIVISIONDWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.love-controls.comP.O. BOX 338 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: love@love-controls.comLit-By Fax: 888/891-4963 SPECIFICATIONSRelative Humidity Range:0 to 100% RHInput: 0 to 3 V humidityprobe (not included).Accuracy: ±1% RH.Display: 3-Digit, Green,1/2” (12.7 mm) digits.Resolution: 1 digit.Temperature Limits: 32 to158°F (0 to 70°C).Storage Temperature: -4to 176°F (-20 to 80°C).Output: 8 A relay @ 250VAC resistive.Horsepower Rating (HP):1/3 HP.Control Type: ON/OFF.Power Requirements: 110VAC or 230 VAC(Depending on model).Memory Backup:Nonvolatile memory.Weight: 2.3 oz (65 g).Front Panel Rating:IP64.Agency Approvals: CE,UL.WIRING DIAGRAMS1 2 3 7 8 9 10 11%H Gnd VccProbePowerSupplyOutput%H1 2 3 7 8 9 10 11%H Gnd VccProbePowerSupplyOutputVcc+ -+-0-1 V and 0-3 V Probes4-20 mA ProbesHS Bulletin 12/2/03 2:12 PM Page 1PARAMETERSDescription Units RangeSP Set point % r1 to r2r0 Differential or Hysteresis % 1 to 99r1 Lower Value Set Point % 0 to r2r2 Higher Value Set Point % r1 to 100 d0 Heating or Cooling Control Option Hu/dHc0 Min. stop time for Load Minutes 0 to 59 min.c1 Continuous Cycle Time Hours 0 to 24 hrsLc HR Value for 4 mA Input % 0 to 100Hc HR Value for 20 mA Input % 50 to 100P1 Probe Adjustment (shifting) % 0 to 10P5 Probe Type Range 0-1 V, 0-3 V, 4-20 mAH5 Parameter Access code Numeric 0 to 99(SET AT 0 FROM FACTORY)PARAMETER DESCRIPTIONSSP= Set Point- Desired Regulation Temperaturer0= Differential or Hysteresisr1= Lower Set Point Limitr2= Higher Set Point Limitd0= Humidifying/Dehumidifying Control-Humidifying: To choose Humidifying Control: Set d0=Hu The output is activated when the relative humidity is less than the Set Point (SP)-r0 and disconnected if the relative humidity is >=SP.Dehumidifying: To choose Dehumidifying Control: Set d0=dH Theoutput is activated when the relative humidity is >SP+r0 and disconnected when the relative humidity is <=SP.c0= Minimum Time Between Start and Stop.c1= Continuous Cycle Time.The time the load is connected when a continuous cycle is activated. To view the programmed cycle time from the display, press the down arrow button for 8 seconds. The display will blink as indication. The output will be connected during the number of hours indicated by the c) parameter. To cancel the continuous cycle, press and hold the down arrow button again for 8 seconds.Lc= RH value for 4 mA input. Parameter for use with 4 to 20 mA output probe.Hc=RH value for 20 mA input. Parameter for use with 4 to 20 mA output probe.P1= Probe Adjustment. Offset degrees to adjust probe. If the probe is not placed in the exact point that is to be measured, use a standard hygrometer and adjust the difference with this parameter.P5= Probe Type. (Set from the factory.) DO NOT ADJUST.H5=Access to Probe Parameters. (The code is set to 0from the factory.)PARAMETER PROGRAMMING Set Point (SP) is the only parameter the user can accesswithout code protection.• Press SET. SP text will appear on the display.• Press SET again. The real value is shown on the display.• The value can be modified with the UP and DOWN arrows.• Press SET to enter any new values.• Press SET and DOWN at the same time to quit programming or wait one minute and the display willautomatically exit programming mode. *The keyboard code can be reset to ZERO by turningoff the controller and turning it on again whilekeeping the SET key depressed.Access to all code protected parameters.• Press SET for 8 seconds. The access code value 00 isshown on the display. (Unit comes with code set at 00 from factory).• With the UP and DOWN arrows, code can be set touser needs.• Press SET to enter the code. If code is correct, the firstparameter label is shown on the display (SP).• Move to the desired parameter with the UP and DOWNkeys.• Press SET to view the value on the display.• The value can be modified with the UP and DOWN arrows.• Press SET to enter the value and exit to text parameter.• Repeat until all necessary parameters are modified.• Press SET and DOWN at the same time to quit programming or wait one minute and the display willautomatically exit programming mode. LED INDICATIONSOUT This indicates the load is connected. The systemwaits for the programmed minimum stop time ofthe load.DISPLAY MESSAGESIn normal operation, the humidity will be shown on the display.In case of alarm or error, the following messages will be shown:• Er = Memory Error• -- = Short-Circuit Probe Error.• oo = Open Probe Error.In the event an error occurs, the unit follows a fixed workingcycle which connects the load for 5 minutes and thendisconnects the load for 5 minutes alternately.MAINTENANCE/REPAIRAfter final installation of the HS Series Digital Humidity Switch, noroutine maintenance is required. A periodic check of system calibrationis recommended. The devices are not field repairable and should bereturned to the factory if recalibration or other service is required. Afterfirst obtaining a Returned Goods Authorization (RGA) number, send thematerial, freight prepaid, to the following address. Please include a clear description of the problem plus any application information available.Dwyer InstrumentsAttn: Repair Department102 Highway 212Michigan City, IN 46360 U.S.ACopyright 2003 Dwyer Instruments, Inc. Printed in the U.S.A. 11/2003 LOVE CONTROLS DIVISIONDWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.love-controls.comP.O. BOX 338 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: love @love-controls.comLit-By Fax: 888/891-4963 HS Bulletin 12/2/03 2:12 PM Page 2
Most popular related searches