Munters AB
- Home
- Companies & Suppliers
- Munters AB
- Downloads
- Munters Dairy Ventilation - Tunnel and ...
Munters Dairy Ventilation - Tunnel and Cross Ventilation
Munters Corporation 4215 Legion Drive • Mason, MI 48854 1-800-227-2376 www.munters.usCross VentilationFeaturing the “Munters Drive” Technologywww.muntersdrive.comCEldek MI-T-edgExpress Coolpres CCs Cs Cs C loolooloolooloolCross Ventialtion ProductsIf your operation experiences a decrease in production during hot weather, Munters Cross or Tunnel Ventilation Systems are your answer to increased pro? ts. Munters Engineers and Sales group average over 25 years of experience in the industry. They can design a system that is speci? c to your operations needs. VX Series FansAerotech FansX Sereriesiiesies FFansAX Circulation FanAerotech FansMunters has engineered the latest advancement in motor technology by developing this unique motor drive system. It is designed for high performance and low energy consumption. The revolutionary motor o? ers up to a 40% reduction in electrical usage and is nearly maintenance free, helping to reduce your carbon foot print, save money and usher in a “greener” approach to agricultural and horticultural ventilation.The motor drive system o? ers three di? erent air? ow and e? ciency options, allowing for a customized approach to ventilation. Options include High E? ciency (HE) for minimum ventilation, High Output (HO) to move a large volume of air , High Rebate (HR) that will maximize output while qualifying for regional energy e? ciency rebates. This motor technology is an excellent addition to Munters’ already innovative product lines, o? ering signi? cant advantages that include energy reduction, no maintenance of belts and bearings, lower installation costs, no variable frequency drive or thermal overloads are required and a soft start-up, eliminating energy spikes. The motor runs cool and quiet, for longer motor and bearing life. The motor is designed to be easily retro? tted to your existing traditional Munters/Aerotech fans. All these savings add up to a powerful return on investment (ROI) and an improved ventilation system.Munters DriveMunters Drive• Reduce energy costs up to 40%• Quali? es for Regional Energy Rebate• Nearly Maintenance Free• No belt, No bearing• Reduced wiring costFeatured in a 51” VX Aerotech fan? Reduce fan energy costs up to 40%? Maintenance FREE - No bearing maintenance - No belts to replace? Reduce your carbon footprint? Optional modes HE, HR, HO providing increased ventilation and savings? Quali? es for energy rebates? Patent Pending?Performance Information: 51” Vortex, Three Phase - 460 Volt Motor and Drive0.00”SP 0.05” SP 0.10” SP 0.15” SP 0.20” SPRPM CFMCFMWatt CFMCFMWattCFMCFMWattCFMCFMWattCFMCFMWattBESSLab TestHigh E? ciency -HE 540 28,200 31.0 26,500 27.6 24,500 24.1 22,100 20.8 19,300 17.7 12201High Rebate - HR 595 31,300 25.8 29,700 23.2 28,000 21.0 26,100 18.8 24,000 16.8 12203High Output - HO 655 34,800 21.2 33,400 19.4 31,900 17.7 30,300 16.2 28,600 14.7 12204Performance Information: 55” Vortex, Three Phase - 460 Volt Motor and Drive0.00”SP 0.05” SP 0.10” SP 0.15” SP 0.20” SPRPM CFMCFMWatt CFMCFMWattCFMCFMWattCFMCFMWattCFMCFM WattBESS Lab TestHigh E? ciency -HE 490 32,000 26.8 30,200 24.1 28,000 21.4 25,500 18.9 22,300 16.3 12197High Rebate - HR 495 32,400 26.3 30,500 23.5 28,300 21.0 25,800 18.6 22,800 16.1 12197High Output - HO 555 36,700 20.9 34,900 19.2 33,000 17.5 31,000 15.9 28,900 14.6 12199Performance Information: 51” Vortex, Three Phase - 460 Volt Motor and Drive0.00”SP 0.05” SP 0.10” SPRPM CFMCFMWattCFMCFMWattCFMCFMWattBESS Lab Test1/2 Air? ow 405 19,900 47.7 17,200 38.1 14,000 29.8 12205Performance Information: 55” Vortex, Three Phase - 460 Volt Motor and Drive0.00”SP 0.05” SP 0.10” SPRPM CFMCFMWattCFMCFMWattCFMCFMWattBESS Lab Test1/2 Air? ow 375 23,300 41.8 20,500 34.4 16,500 27.0 12200Notes:1.The ratings shown are based on tests and procedures performed at the BESS Lab, University of Illinois in accordance with ASHRAE Standard 51-1999.Only Munters gives you a choice of systems with the ? exibility to precisely match your needs. Each system utilizes the natural cooling e? ect of evaporation to e? ciently cool the air entering your buildings. Combined with the windchill e? ect of tunnel ventilation, these systems improve production in the hottest weather. Modular pad assembly holds and wets a choice of pad materials for the ultimate in e? cient and e? ective cooling. Inlet air temperatures can be reduced by 10-20 Fº on most days, and even more under ideal conditions.CT SeriesCT Series Evaporative Cooling• Corrosion resistant header• Spray de? ector ensures uniform pad wetting• Removable pad retainer for easy cleaning• Cooling pads easily lift outCT Header• Corrosion resistant extruded aluminum header• Spray de? ector ensures uniform pad wetting• Removable pad retainer for easy clean- ing, open view header option available• Cooling pads easily lift outCT Footer• Custom designed drip collectors for maximum water capacity & easy installation• Simple to install drain ? ttings• UV resistant PVC reservoir• Heavy duty extruded aluminum wall mounting bracketsStacked pad system• If your application requires a height over 72", Munters o? ers the stacked pad system which allows you to increase the system height to a maximum of 120"FeaturesCT HeaderHeaderPad retainer Spray deflectorCooling padsDrip collectorsPVC reservoirCT FooterDrain fittingsMounting bracketsTank kits are used with the CN and CT self contained cooling systems and are available for submersible and non-submersible pumps. Options include end and center draw supplied with either 10" or 15" diameter sumps. Kits include the necessary plumbing ? ttings to complete your system (pump sold separately). Tank KitsEconomical high performance AX Aerotech fan with "air-foil" technology provide the features you like at a price you'll love. High e? ciency and high air? ow coupled with outstanding durability and reliability are hard to beat. The AX line is ideal for noncorrosive environments. Heavy-gauge galvanized-steel panels, supports and high strength galvanized tubular struts provide a superior core for the fan. High quality, greaseable, cast iron pillow block bearings assure longer life. Large pulleys provide greater belt wrap. This means belt tension can be lower without slippage. Less stress increases life for the belts and bearings. With a selection of sizes, housings, discharge cones, guards and shutter options the AX is sure to ? t your application.AX Circulation Fans (formerly Apex)AX Circulation Fans• Durable cast aluminum prop.• Solid galvanized steel panels and tubular support strut• High velocity air ? ow• USA Quality partsCELdekCELdek evaporative cooling pads are designed to provide maximum cooling, low pressure drop and years of reliable service. It is made from speci? cally engineered cellulose paper that is chemically treated to resist deterioration. Our cross ? uted, unequaled angle pad design promotes the bene? cial mixing of air and water for optimum cooling. This unique design also functions to continually direct more water to the air entering face of the pad, where the air is the hottest, driest, dirtiest and the most intense evaporation occurs. MI-T-edg™ by Munters is a tough and resilient optional edge treatment applied to the air entering face of a CELdek pad. It has been formulated to withstand repeated cleaning without damaging the pad and prevents algae growth.®CELdek Pad• MI-T-edg protection, resists algae and creates a durable surface• Wets and drys fast for higher performance and longer life• High Cooling e? ciency®For regional representative information contact :USA Munters Corporation Mason • 4215 Legion Drive • Mason, MI 48854 • Phone +1 800. 227.2376 www.munters.us
Most popular related searches
