Our special generator head-handle not only allows precise positioning, it makes the process more comfortable for both the operator and the patient.

Most popular related searches

Advanced ergonomics for advanced comfort
Our special generator head-handle not only allows precise positioning, it makes the process more comfortable for both the operator and the patient.

DC tube to minimize radiation dosage
DC tube guarantees constant level energy for brilliant images. Reduces the patient dose by more than 25% in comparison to conventional AC units, ensuring greater safety for your patients and staff.

Control panel for faster workflow and fewer errors
User-friendly display features intuitive icons for quick and accurate selection of tooth area, size of patient, type of radiograph remotely using CAT-5 cable.

Space-saving design
This state-of-the-art design with small footprint and right angle/parallel technology, allows for installation and operation in less space.

  • HIGH RESOLUTION
  • SPECIFICALLY FOR VETS
  • INTUITIVE DISPLAY CONTROL
  • REMOTE SWITCH CAPABILITY

Ergonomic design
Simple and flexible operation.

Easy positioning
Generator head-handle allows precise positioning that stays in place.

Easy alignment
Right-angle/parallel technology for precise alignment.

Multi-functional display

  • kV, mA, sec, DAP indicator
  • Change between PSP/Sensor or Film/Sensor
  • Change of tooth area
  • Change between small and large animal
  • Expose button (in addition to the hand switch)

Unsurpassed image resolution

  • While most X-ray units have a 0.7 mm focal point, the ProVectaHD features a 0.4 mm focal point for maximum image sharpness.
  • The smaller the focal spot, the greater the contras resolution, which provides sharper edge definition and finer details of internal structures.

  • Power input: AC 100 - 240 V +/- 10% , 50/60 Hz
  • Power rating: 500 W
  • Tube voltage: 60 - 70 kVp
  • Tube current: 4 - 7 mA
  • Tube length: 8“ (12“ optional)
  • Radiation field limits: 2.4“/1.2“ x 1.6“ (0.8“ x 1.2“ optional)
  • Exposure time: 0.04 - 2 sec
  • Focal spot size: 0.4 mm (IEC 60336)
  • Total filtration: Min. 2.0 mm Al
  • Weight: 55/56/59 lbs (short/medium/long arm)
  • Storage height: 46"
  • Extended arm length: 66", 72" and 84"