Delta Hydronics
5 products found

Delta Hydronics products

Hydromarine Chiller & Heat Pump

Delta - 1.5 - 5.0 Tons - Hydromarine Chiller

Gr.2 titanium tube heat exchanger coil, Normal operating ambient air temperature: 50 f - 115 f, All condensing units have a 14 seer rating., Top discharge area should be unrestricted for 48 inches minimum, Avoid placing unit in direct area of roof runoff or constant water flow, Consult carrier specified condenser clearances when placing unit(s), SCH 80 PVC shell construction with removable flanged ends, All 316 SS base, jacket and hardware, Temperature controller can be set +/- 0.1° f/c. Recommended minimum setpoint is 50°f, Unit arrives charged with r-410a refrigerant, Factory mounted & wired flow switch.

Delta - 6 - 12 Tons Hydromarine Chiller

Condenser and skid mounted on 4” marine grade aluminum square tube, Gr.2 titanium tube heat exchanger coils, Normal operating ambient air temperature: 50 f - 115 f, All condensing units have EER of 11 or better., Top discharge area should be unrestricted for 48 inches minimum, Avoid placing unit in direct area of roof runoff or constant water flow, Consult carrier specified condenser clearances when placing unit(s), SCH 80 PVC shell construction with removable flanged ends, All 316 SS base, jacket and hardware, Temperature controller can be set +/- 0.1° f/c. Recommended minimum setpoint is 50°f, Unit arrives charged with r-410a refrigerant, Hail guard.

Delta - 15 & 20 Tons Hydromarine Chiller

Condenser and skid mounted on 4” marine grade aluminum square tube, Gr.2 titanium tube heat exchanger coils, Normal operating ambient air temperature: 50 f - 115 f, All condensing units have EER of 11 or better., Top discharge area should be unrestricted for 48 inches minimum, Avoid placing unit in direct area of roof runoff or constant water flow, Consult carrier specified condenser clearances when placing unit(s), SCH 80 PVC shell construction with removable flanged ends, All 316 SS base, jacket and hardware, Temperature controller can be set +/- 0.1° f/c. Recommended minimum setpoint is 50°f, Unit arrives charged with r-410a refrigerant, Hail guard.

Delta - 1.5 - 5.0 Tons Hydromarine Heat Pump

Gr.2 titanium tube heat exchanger coil, Normal operating ambient air temperature: 50 f - 115 f, All condensing units have a 14 seer rating., Top discharge area should be unrestricted for 48 inches minimum, Avoid placing unit in direct area of roof runoff or constant water flow, Consult carrier specified condenser clearances when placing unit(s), SCH 80 PVC shell construction with removable flanged ends, All 316 SS base, jacket and hardware, Temperature controller can be set +/- 0.1° f/c. Recommended minimum setpoint is 50°f, Unit arrives charged with r-410a refrigerant.

Delta - 6 To 10 Tons Hydromarine Heat Pump

Condenser and skid mounted on 4” marine grade aluminum square tube, Gr.2 titanium tube heat exchanger coils, Normal operating ambient air temperature: 50 f - 115 f, All condensing units have EER of 11 or better., Top discharge area should be unrestricted for 48 inches minimum, Avoid placing unit in direct area of roof runoff or constant water flow, Consult carrier specified condenser clearances when placing unit(s), SCH 80 PVC shell construction with removable flanged ends, All 316 SS base, jacket and hardware, Temperature controller can be set +/- 0.1° f/c. Recommended minimum setpoint is 50°f, Unit arrives charged with r-410a refrigerant, Hail guard.