Dr. Sherlock - Rolls-Royce Livestock Housing Alarm System
Dr. Sherlock is our Rolls-Royce alarm system model for professional livestock production. The user friendly monitor with digital display greatly simplifies operation. This system can monitor that ventilation is operated at the optimum in up to 10 housing units. The integrated audio computer provides an acoustic alarm message that describes the nature of the problem. The fault message is simultaneously sent to up to 5 mobile telephones. Dr. Sherlock is available in both GSM and telephone network models and can be installed in the majority of ventilation and monitoring system brands. Please request further information.
Easy operation
- Right turnable button provides easy access to the menus
- Left turnable button is used to select which input changes apply to etc.
- Alarm condition is provided in meaningful text
- Logical structure and self explanatory interface making a manual more or less superfluous
- Speech processor commands are shown and can be changed directly
User settings
- Input names can be changed. Changes are automatically transferred to the speech computer
- Each input can be set as either a temperature input or ON/OFF input
Perfect survey
- Temperatures and status for each input are show in the display
- Everything can be set directly from the panel - no external adjustment are needed
Alarms
- High and low absolute temperature alarm limits
- High and low relative temperature alarm limits compared to a "normal temperature" measured between 6 and 7 in the morning
- In addition to lightning/transient protection short (insignificant) alarms are filtered
Selective alarm handling
Alarm handling can be set for each input as needed:
- both siren and alarm dialup.
- siren only
- only during daytime hours
- as beep only and on request only (soft alarm)
Heat wave compensation
In order to avoid unwanted alarms on a warm summer day (heat wave), it is possible to specify a parameter in °C by which the indoor temperature is allowed to rise above the outdoor temperature. This can be done separately for each input.
Safety
- Alarm for defects - short circuits and broken cables - at all inputs.
- Alarm at too low voltage in power supply.
- Temperature sensors and keyboard housing are IP 65.
- Possibility for automatic test of accumulator every day at 0800 hrs.
Graphical survey
Clear and easy graphical survey with:
- Temperature trends shown as curves
- High and low values
- Alarm condition
Speech Processor
- A Speech Processor Dr.Bell performs alarm dialup and informs in clear speech.
- Remote control - setting parameters using a telephone.
Communication
RS485 interface is integrated. Communication opens up possibilities which you will soon appreciate:
- Communication with a PC and Professor Partyline for presentation of trends of the temperature. Remote control - for example setting of alarm limits and toggle active/idlemode of each input. This can also be done through telephone by means of a modem.
- By means of a Speech Processor Dr.Bell inquiries and operation can also be done through telephone.
Expansion Possibilities
- Can be expanded by more units connected in network.
- Supervision of O2 and pH-value and other parameters on request.