PFS Series - Irrigation Flow Sensors
The Baseline PFS Series Flow Sensors have a unique low drag, a lightweight impeller design, and a specially engineered tee cavity and impeller placement to ensure smooth flow and precise performance at the lowest flow rates. Every Baseline PFS Series Flow Sensor is two-wire ready with a Flow biCoder built into the tee insert. Because a Flow biCoder is built into each flow sensor, every device comes pre-configured with the correct K and offset values. The PFS Series Flow Sensors are available in 1½” to 4” sizes.
Specification
Flow biCoders™
Features
- The Flow biCoder has true two-way communication using a 9-byte packet for commands and replies.
- The Flow biCoder is capable of self-identifying to the two-wire controller and will report pre-configured unique serial numbers and zone addresses.
- The Flow biCoder serial number is printed on the side of the decoder.
- Each Flow biCoder has 24 inches of 16-gauge PVC jacketed solid core wire to connect to the two-wire.
- Each Flow biCoder has 24 inches of 18-gauge PVC jacketed stranded core wire to connect to a pulse output flow meter.
- The Flow biCoder can be connected to flow devices with either 2 or 3 wires.
- The Flow biCoder has collision detection on the two-wire and is able to resend messages if a collision is detected.
- The Flow biCoder reads a minimum of a 5-millisecond low pulse at 200 hertz and a maximum of 200 pulses per second.
- The Flow biCoder is able to search for a flow meter.
- The Flow biCoder is able to run a pulse-output flow meter up to 1000 feet away.
- The Flow biCoder has a built-in amperage meter to accurately measure and diagnose flow meter electrical problems such as “no current,” “station short,” or “over current.”
Connection Requirements
- Use two-wire connectors that are DBR/Y or equivalent direct bury splice, made for full submersion and effectively seal moisture out.
- Make all connections per manufacturer’s specifications.
- Verify that no loose, unshielded wiring can touch the soil, water, or another copper conductor causing a leakage of current to the ground or a short circuit across wires.
- Make all splices inside a valve box.
- Mount all connections vertically to eliminate standing water inside the DBR/Y connector.
Flow Features in the Irrigation Controller Software
- Learn the flow for each zone
- Use flow data to maximize the number of zones the controller can turn on at once to help shorten your water windows
- In the event of unexpected high or low flow, automatically determine which zone is at fault and alert you without interrupting the rest of the watering cycle
- Protect your site from mainline breaks with configurable high and low flow shutdown settings
Baseline's Irrigation Flow Sensors and Flow Meters
PFS Series Flow Sensor Features
- Molded Mounting Tee - improved sensor accuracy and low flow performance
- Threaded Retaining Nut - easier to service in valve box, more moisture resistant than competitive sensors
- Lightweight Impeller - improved low flow performance, detects and measures flows as low as 0.20 ft/sec
- Built-in two-wire decoder
- Pre-configured K and Offset values
- Sensor can be connected directly to the two-wire path on any Baseline controller - no additional equipment required
- Diagnostic LEDs - visual indication of flow, improved troubleshooting
- Detects and properly measures lower flow rates - compatible with micro and subsurface drip applications
- Highly accurate over a large range of flows
- Available in 1”, 1.5”, 2”, 3” and 4” versions
PFS Series Flow Sensor Specifications
- Wetted Materials:
- Impeller: High Density Polyethylene
- Shaft: Tungsten Carbide
- O-ring: BUNA N
- Tee, housing and retaining nut: Type 1 PVC
- Connection Type
- 1', 1.5', & 2' Slip
- 3' & 4' Saddle mount
- Maximum Working Pressure
- 1', 1.5', & 2' 240 psi
- 3' & 4' 150 psi
- Recommended Flow Range
- 1', 1.5', & 2' 0.25 to 15 FPS
- 3' & 4' 0.25 to 12 FPS
- Pressure Rating: designed to Schedule 40 specifications
- Electrical Output: Baseline two-wire, 30 VAC RMS
- Temperature Range: 32°F to 140°F (0°C to 60°C)
- Accuracy: better than ±1% within recommended flow range
- Repeatability: better than ±0.3% within recommended flow range
BFS Brass Flow Sensor Features
- Brass bodied sensor with female NPT connections
- Threaded Retaining Nut - easier to service in valve box, more moisture resistant than competitive sensors
- Lightweight Impeller - improved low flow performance, detects and measures flows as low as 0.50 ft/sec
- Built-in two-wire decoder
- Pre-configured K and Offset values
- Sensor can be connected directly to the two-wire path on any Baseline controller - no additional equipment required
- Diagnostic LEDs - visual indication of flow, improved troubleshooting
- Highly accurate over a large range of flows
- Available in 1½”
BFS Brass Flow Sensor Specifications
- Wetted Materials:
- Impeller: High Density Polyethylene
- Shaft: Tungsten Carbide
- O-ring: BUNA N
- Tee, housing and retaining nut: Type 1 PVC
- Body and Retaining Nut Material: Lead free Bronze Alloy C89833 Federalloy® I-836
- Connection Type
- Female Pipe Thread (NPT)
- Maximum Working Pressure
- 250 psi
- Recommended Flow Range
- 0.50 to 15 FPS
- 3 to 90 gpm
- Electrical Output: Baseline two-wire, 30 VAC RMS
- Temperature Range: 32°F to 140°F (0°C to 60°C)
BFM Series Flow Meter Features
- Small, rugged, highly reliable - only one moving part
- No straight pipe installation requirement
- Highly accurate over a large range of flows
- Magnetically driven sealed register with totalizer
- Baseline two-wire ready - no decoder required
- Compatible with all Baseline controllers
- Pre-configured K and Offset values
BFM Series Flow Meter Specifications
- Maximum Working Pressure: 140 psi
- Maximum Liquid Temperature: 122oF (50oC)
- Body Material: Corrosion Proof Copper Alloy with Polyester Coating
- Connections: Male Pipe Thread (NPT)
- Electrical: Baseline two-wire (30 VAC RMS)
BHM Series Hydrometer & Master Valve
- Combination master valve, water meter, and flow sensor
- Rugged, heavy-duty construction
- Fast and highly reliable double-chambered valve
- No straight pipe installation requirement
- Highly accurate over a large range of flows
- Magnetically driven sealed register with totalizer
- Baseline two-wire ready – no additional decoders required
- Compatible with all Baseline controllers
- Pre-configured K and Offset values
- Optional pressure regulation available
BHM Series Hydrometer Specifications
- Maximum Working Pressure: 235 psi
- Minimum Working Pressure: 14 psi
- Connections: National Pipe Thread or ANSI Flange
- Body Material: Cast Iron with Polyester Coating
- Diaphragm Material: Reinforced natural rubber
- Electrical: Baseline two-wire (30 VAC RMS)
Customer reviews